Phoenix Contact MACX PL-EX-T-UIREL-UP | Transducer

I.S. Barriers With Functional Safety

Features:
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal inputs, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, screw connection, PLd
  • Product type:                                  Temperature transmitter
Insulation characteristics
  • Overvoltage category:                     II
  • Pollution degree:                             2
  • Electrical isolation:                          4-way, between input/output/power supply/switching output
  • Step response (0–99%):                  1000 ms (With SIL)
                                                                 700 ms (Without SIL)
  • Maximum temperature coefficient: 0.01 %/K
  • Maximum transmission error:          0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Electrical isolation Input/output/power supply
  • Test voltage:                                       2.5 kV AC (50 Hz, 60 s)



Phoenix Contact MACX PL-EX-T-UIREL-UP | Transducer

I.S. Barriers With Functional Safety

Features:
Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal inputs, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, screw connection, PLd
  • Product type:                                  Temperature transmitter
Insulation characteristics
  • Overvoltage category:                     II
  • Pollution degree:                             2
  • Electrical isolation:                          4-way, between input/output/power supply/switching output
  • Step response (0–99%):                  1000 ms (With SIL)
                                                                 700 ms (Without SIL)
  • Maximum temperature coefficient: 0.01 %/K
  • Maximum transmission error:          0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Electrical isolation Input/output/power supply
  • Test voltage:                                       2.5 kV AC (50 Hz, 60 s)